EasyManuals Logo
Home>Lennox>Air Handlers>LGH092H4M

Lennox LGH092H4M User Manual

Lennox LGH092H4M
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Page 9
SPECIFICATIONS - 120H, 150S
General Data Nominal Tonnage 10 Ton 10 Ton 12.5 Ton 12.5 Ton
Model Number LGH120H4B LGH120H4M LGH150S4B LGH150S4M
Efciency Type High High Standard Standard
Blower Type Constant Air
Volume CAV
Multi-Stage Air
Volume
Constant Air
Volume CAV
Multi-Stage Air
Volume
Cooling
Performance
Gross Cooling Capacity - Btuh 122,000 122,000 142,600 142,600
1
Net Cooling Capacity - Btuh 118,000 118,000 138,000 138,000
AHRI Rated Air Flow - cfm 3600 3300 4300 4300
Total Unit Power - kW 9.9 9.8 12.5 12.5
1
EER (Btuh/Watt) 12 12.0 11.0 11.0
2
IEER (Btuh/Watt) 13.0 13.8 11.4 13.1
Refrigerant Type R-410A R-410A R-410A R-410A
Refrigerant
Charge
All-Aluminum Coil
System
Circuit 1 7 lbs. 4 oz. 7 lbs. 4 oz. 7 lbs. 4 oz. 7 lbs. 4 oz.
Circuit 2 7 lbs. 8 oz. 7 lbs. 8 oz. 6 lbs. 12 oz. 6 lbs. 12 oz.
Conventional Fin/Tube
Coil Option
Circuit 1 14 lbs. 8 oz. 14 lbs. 8 oz. 16 lbs. 8 oz. 16 lbs. 8 oz.
Circuit 2 13 lbs. 8 oz. 13 lbs. 8 oz. 14 lbs. 8 oz. 14 lbs. 8 oz.
Conventional Fin/Tube
With Humiditrol
®
Circuit 1 18 lbs. 0 oz. 18 lbs. 0 oz. 18 lbs. 8 oz. 18 lbs. 8 oz.
Circuit 2 13 lbs. 8 oz. 13 lbs. 8 oz. 14 lbs. 8 oz. 14 lbs. 8 oz.
Gas Heating Options Available - See page 10 Standard (2 Stage), Medium (2 Stage), High (2 Stage)
Compressor Type (number) Scroll (2) Scroll (2) Scroll (2) Scroll (2)
Outdoor Coils
Aluminum
(Fin/Tube)
Net face area (total) - sq. ft. 28.0 (29.33) 28.0 (29.33) 28.0 (29.33) 28.0 (29.33)
Number of rows 1 (3) 1 (3) 1 (3) 1 (3)
Fins per inch 20 (20) 20 (20) 20 (20) 20 (20)
Outdoor
Coil Fans
Motor - (No.) hp (2) 1/3 (2) 1/3 (2) 1/2 (2) 1/2
Motor rpm 1075 1075 1075 1075
Total Motor watts 800 800 1050 1050
Diameter - (No.) in. (2) 24 (2) 24 (2) 24 (2) 24
Number of blades 3 3 3 3
Total Air volume - cfm 8800 8800 9700 9700
Indoor
Coils
Net face area (total) - sq. ft. 13.54 13.54 13.54 13.54
Tube diameter - in. 3/8 3/8 3/8 3/8
Number of rows 4 4 4 4
Fins per inch 14 14 14 14
Drain connection - Number and size (1) 1 in. NPT coupling
Expansion device type Balance port TXV, removable head
5
Refrigerant Metering Orice (RFC)
3
Indoor
Blower and
Drive
Selection
Nominal motor output 2 hp, 3 hp, 5 hp
Maximum usable motor output
(US Only)
2.3 hp, 3.45 hp, 5.75 hp
Motor - Drive kit number 2 hp
Kit 1 590-890 rpm (std. and high efciency)
Kit 2 800-1105 rpm (std. and high efciency)
Kit 3 795-1195 rpm (std. and high efciency)
3 hp
Kit 4 730-970 rpm (std. efciency)
Kit 5 940-1200 rpm (std. efciency)
Kit 6 1015-1300 rpm (std. efciency)
Kit 7 730-970 rpm (high efciency)
Kit 8 940-1200 rpm (high efciency)
Kit 9 1015-1300 rpm (high efciency)
5 hp
Kit 10 900-1135 rpm (std. efciency)
Kit 11 1040-1315 rpm (std. efciency)
Kit 12 1125-1425 rpm (std. efciency)
Blower wheel nominal diameter x width - in. (1) 15 X 15 (1) 15 X 15 (1) 15 X 15 (1) 15 X 15
Filters Type of lter Disposable
Number and size - in. (4) 20 x 25 x 2
Electrical characteristics 208/230V, 460V or 575V - 60 hertz - 3 phase
NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction.
1
AHRI Certied to AHRI Standard 340/360; 95°F outdoor air temperature and 80°F db/67°F wb entering evaporator air; minimum external duct static pressure.
2
Integrated Energy Efciency Ratio certied and tested according to AHRI Standard 340/360.
3
Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of
motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within
the service factor limitations outlined on the motor nameplate.
5
150 models ordered with the Humiditrol
®
Dehumidication option are equipped with factory installed expansion valves.
NOTE – Units equipped with Multi-Stage Air Volume option are limited to a motor service factor of 1.0.

Table of Contents