ML193UH / Page 6
SPECIFICATIONS
Gas
Heating
Performance
Model No. ML193UH045P24B ML193UH045P36B ML193UH070P24B
1
AFUE 93% 93% 93%
Input - Btuh 44,000 44,000 66,000
Output - Btuh 41,000 42,000 62,000
Temperature rise range - °F 40 - 70 25 - 55 50 - 80
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
High static - in. w.g. 0.50 0.50 0.50
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 1/2 1/2 1/2
with eld supplied (PVC coupling) - o.d. 3/4 3/4 3/4
Indoor
Blower
Wheel nom. dia. x width - in. 10 x 8 10 x 8 10 x 8
Motor output - hp 1/5 1/3 1/5
Tons of add-on cooling 1.5 - 2 2.5 - 3 1.5 - 2
Air Volume Range - cfm 390 - 1140 700 - 1600 390 - 1140
Electrical
Data
Voltage 120 volts - 60 hertz - 1 phase
Blower motor full load amps 3.1 6.1 3.1
Maximum overcurrent protection 15 15 15
Shipping Data lbs. - 1 package 120 122 125
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization Efciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
furnaces.
SPECIFICATIONS
Gas
Heating
Performance
Model No. ML193UH070P36B ML193UH090P36C ML193UH090P48C
1
AFUE 93% 93% 93%
Input - Btuh 66,000 88,000 88,000
Output - Btuh 62,000 83,000 83,000
Temperature rise range - °F 40 - 70 50 - 80 40 - 70
Gas Manifold Pressure (in. w.g.)
Nat. Gas / LPG/Propane
3.5 / 10.0 3.5 / 10.0 3.5 / 10.0
High static - in. w.g. 0.50 0.50 0.50
Connections
in.
Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2
Gas pipe size IPS 1/2 1/2 1/2
Condensate Drain Trap (PVC pipe) - i.d. 1/2 1/2 1/2
with eld supplied (PVC coupling) - o.d. 3/4 3/4 3/4
Indoor
Blower
Wheel nom. dia. x width - in. 10 x 8 10 x 8 10 x 10
Motor output - hp 1/3 1/3 1/2
Tons of add-on cooling 2.5 - 3 2 - 3 3 - 4
Air Volume Range - cfm 660 - 1615 695 - 1620 900 - 2025
Electrical
Data
Voltage 120 volts - 60 hertz - 1 phase
Blower motor full load amps 6.1 6.1 8.2
Maximum overcurrent protection 15 15 15
Shipping Data lbs. - 1 package 127 143 146
NOTE - Filters and provisions for mounting are not furnished and must be eld provided.
1
Annual Fuel Utilization Efciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized
furnaces.

Other manuals for Lennox ML193UH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox ML193UH and is the answer not in the manual?

Lennox ML193UH Specifications

General IconGeneral
BrandLennox
ModelML193UH
CategoryFurnace
LanguageEnglish

Related product manuals