ML193UH / Page 9
VENT LENGTHS - FEET
STANDARD TERMINATION AT ELEVATION 0 - 10,000 ft.
Pipe Size 2 in. 2-1/2 in. 3 in.
Input 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135
No. of
90 ELL
1 81 66 44 24 N/A 115 100 68 43 N/A 137 137 118 118 114
2 76 61 39 19 N/A 110 95 63 38 N/A 132 132 113 113 109
3 71 56 34 14 N/A 105 90 58 33 N/A 127 127 108 108 104
4 66 51 29 N/A N/A 100 85 53 28 N/A 122 122 103 103 99
5 61 46 24 N/A N/A 95 80 48 23 N/A 117 117 98 98 94
6 56 41 19 N/A N/A 90 75 43 18 N/A 112 112 93 93 89
7 51 36 14 N/A N/A 85 70 38 13 N/A 107 107 88 88 84
8 46 31 N/A N/A N/A 80 65 33 N/A N/A 102 102 83 83 79
9 41 26 N/A N/A N/A 75 60 28 N/A N/A 97 97 78 78 74
10 36 21 N/A N/A N/A 70 55 23 N/A N/A 92 92 73 73 69
CONCENTRIC TERMINATION ELEVATION 0 - 10,000 ft.
Pipe Size 2 in. 2-1/2 in. 3 in.
Input 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135
No. of
90 ELL
1 73 58 42 22 N/A 105 90 64 39 N/A 121 121 114 114 105
2 68 53 37 17 N/A 100 85 59 34 N/A 116 116 109 109 100
3 63 48 32 12 N/A 95 80 54 29 N/A 111 111 104 104 95
4 58 43 27 N/A N/A 90 75 49 24 N/A 106 106 99 99 90
5 53 38 22 N/A N/A 85 70 44 19 N/A 101 101 94 94 85
6 48 33 17 N/A N/A 80 65 39 14 N/A 96 96 89 89 80
7 43 28 12 N/A N/A 75 60 34 N/A N/A 91 91 84 84 75
8 38 23 N/A N/A N/A 70 55 29 N/A N/A 86 86 79 79 70
9 33 18 N/A N/A N/A 65 50 24 N/A N/A 81 81 74 74 65
10 28 13 N/A N/A N/A 60 45 19 N/A N/A 76 76 69 69 60
TERMINATION KITS USAGE
Input
Size
Vent Pipe
Diameter
in.
Concentric Terminations Standard Terminations
Concentric
Kits
Close Couple
Kits
Wall
Ring
Kit
Flush
Mount
kit
Outdoor Exhaust
Accelerator
(Diameter X Length)
For use with Close
Couple and Wall Ring Kits
2 in. 3 in. 2 in. 3 in. 2 in.
2, 2-1/2
or 3 in.
1-1/2 x 12 in. 2 x 12 in.
3
71M80
3, 4
44W92
69M29
60L46
4
44W93
22G44
4
30G28
44J40
4
81J20
15F74 51W11 Field Provided
045
2 Yes - - - - - - Yes
1
Yes Yes Yes Yes - - -
2-1/2 Yes - - - - - - Yes
1
Yes Yes Yes Yes - - -
3 Yes - - - - - - Yes
1
Yes Yes Yes Yes - - -
070
2 Yes - - - - - - Yes
1
Yes Yes Yes Yes - - -
2-1/2 Yes - - - - - - Yes
1
Yes Yes Yes Yes - - -
3 Yes - - - - - - Yes
1
Yes Yes Yes Yes - - -
090
2 - - - Yes Yes - - - Yes
2
Yes Yes - - - Yes
2-1/2 - - - Yes Yes - - - Yes
2
Yes Yes - - - Yes
3 - - - Yes Yes - - - Yes
2
Yes Yes - - - Yes
110
2 - - - Yes Yes - - - Yes - - - Yes - - - Yes
2-1/2 - - - Yes Yes - - - Yes - - - Yes - - - Yes
3 - - - Yes Yes - - - Yes - - - Yes - - - Yes
135 3 - - - - - - Yes - - - Yes - - - Yes - - - Yes
1
Requires eld provided 1-1/2 in. outdoor exhaust accelerator.
2
Requires eld provided 2 in. outdoor exhaust accelerator.
3
Concentric Kits 71M80 and 44W92 include 1-1/2 in. outdoor exhaust accelerator, required when used with 045, 070 input models. Accelerator is not used with 090, 110,
135 input models.
4
Termination Kits 44W92, 44W93, 30G28, 81J20 are certied to ULC S636 standard for use in Canada only.