2
Lenze
2-4
8200 motec/starttec en 12/03
Standard controllers
8200 motec – Technical data
Conformity CE Low Voltage Directive (73/23/EEC)
Approvals UL 508C Underwriter Laboratories (File No. E132659)
Power Conversion Equipment
Vibrational stability Accelerational stability up to 2 g (Germanischer Lloyd, general conditions)
Climatic conditions Class 3K3 to EN 50178 (without condensation, average relative humidity 85%)
Pollution degree VDE 0110 Part 2, pollution degree 2
Packaging (DIN 4180) Dust packaging
Permissible temperature ranges
Transport -25°C ... +70°C
Storage -25°C ... +60°C
Operation -20°C ... +60°C At temperatures of +40°C, the rated output current
should be derated by 2.5%/°C.
Permissible installation height 0 ... 4000 m above The rated output current should be derated by 5%/1000 m
sea level above 1000 m above sea level.
Mounting positions All mounting positions and mounting orientations permitted
Mounting space
Above/below ≥100 mm
To the side ≥100 mm
DC bus connection Not possible
Standards and operating conditions