2
Lenze
2-4
8200 motec/starttec en 12/03
Standard controllers
8200 motec – Technical data
Conformity CE Low Voltage Directive (73/23/EEC)
Approvals UL 508C Underwriter Laboratories (File No. E132659)
Power Conversion Equipment
Vibrational stability Accelerational stability up to 2 g (Germanischer Lloyd, general conditions)
Climatic conditions Class 3K3 to EN 50178 (without condensation, average relative humidity 85%)
Pollution degree VDE 0110 Part 2, pollution degree 2
Packaging (DIN 4180) Dust packaging
Permissible temperature ranges
Transport -25°C ... +70°C
Storage -25°C ... +60°C
Operation -20°C ... +60°C At temperatures of +40°C, the rated output current
should be derated by 2.5%/°C.
Permissible installation height 0 ... 4000 m above The rated output current should be derated by 5%/1000 m
sea level above 1000 m above sea level.
Mounting positions All mounting positions and mounting orientations permitted
Mounting space
Above/below ≥100 mm
To the side ≥100 mm
DC bus connection Not possible
Standards and operating conditions
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: info@ctiautomation.net

Other manuals for Lenze 8200 motec

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8200 motec and is the answer not in the manual?

Lenze 8200 motec Specifications

General IconGeneral
BrandLenze
Model8200 motec
CategoryDC Drives
LanguageEnglish

Related product manuals