2
Lenze
2-9
8200 motec/starttec en 12/03
Typical motor power P
r
[kW] 0.25 0.37
Three-phase asynchronous motor (4-pole) P
r
[hp] 0.34 0.5
8200 motec type E82MV251_2B E82MV371_2B
Mains voltage U
mains
[V] 1/N/PE AC 180 V-0%...264 V +0%; 45 Hz -0%...65 Hz +0%
Data for operation at 1/N/PE 230 V AC
Rated mains current I
mains
[A] 3.4 5.0
Output power U, V, W (at 8 kHz) S
r
[kVA] 0.68 1.0
Rated output 2 kHz
I
r
[A] 2.0 2.9
current at switching
4 kHz
frequency
8 kHz I
r
[A] 1.7 2.4
16 kHz
2)
I
r
[A] 1.1 1.6
Max. permissible output 2 kHz
I
max
[A] 2.5 3.6
current for 60 s
4 kHz
at switching frequency
1)
8 kHz I
max
[A] 2.5 3.6
16 kHz
2)
I
max
[A] 1.7 2.3
Output voltage U
M
[V] 3~ 0 ... U
mains
/0 ... 650 Hz
Power loss (operation at I
r
at 8 kHz) P
v
[W] 30 40
Dimensions H xBxT [mm] 190 x 138 x 100
Weight m [kg] 1.8 1.8
Ratings at 230 V mains voltage
Bold text = Data for operation at a switching frequency of 8 kHz (Lenze
setting)
1)
Currents for periodic load change cycle: 1 min overcurrent duration at I
max
2
min base load duration at 75% I
r
2)
To protect the inverter shutting down in the event of overtemperatures, before
the shutdown temperature is reached, the switching frequency automatically
drops to 4 kHz.
Standard controllers
8200 motec – Operation at rated power (normal operation)