2
Lenze
2-11
8200 motec/starttec en 12/03
Typical motor power P
r
[kW] 3.0 4.0 5.5 7.5
Three-phase asynchronous motor (4-pole) P
r
[hp] 4.1 5.4 7.5 10.2
8200 motec type E82MV302_4B E82MV402_4B E82MV552_4B E82MV752_4B
Mains voltage U
mains
[V] 3/PE AC 320 V - 0% ... 550 V + 0% ; 45 Hz - 0% ... 65 Hz + 0%
Data for operation at 3/PE AC 400 V
Rated mains current I
mains
[A] 9.5 12.3 16.8 21.5
Output power U, V, W (at 8 kHz) S
r
[kVA] 5.1 6.6 9.0 11.4
Rated output 2 kHz
I
r
[A] 8.8 11.4 15.6 16.5
current at switching
4 kHz
frequency
8 kHz I
r
[A] 7.3 9.5 13.0 16.5
16 kHz
2)
I
r
[A] 4.7 6.1 8.4 10.7
Max. permissible output 2 kHz
I
max
[A] 11.0 14.2 19.5 24.8
current for 60 s
4 kHz
at switching frequency
1)
8 kHz I
max
[A] 11.0 14.2 19.5 24.8
16 kHz
2)
I
max
[A] 7.1 9.1 12.7 16.1
Output voltage U
M
[V] 3~ 0 ... U
mains
/0 ... 650 Hz
Power loss (operation at I
r
at 8 kHz) P
v
[W] 140 180 230 290
Dimensions HxBxT [mm] 325 x 211 x 163 (223)
3)
Weight m [kg] 9.7 (11.4)
3)
Ratings at 400 V mains voltage
Standard controllers
8200 motec – Operation at rated power (normal operation)
1)
Currents for periodic load change cycle: 1 min overcurrent duration at
I
max
2 min base load duration at 75% I
r
2)
To protect the inverter shutting down in the event of overtemperatures,
before the shutdown temperature is reached, the switching frequency
automatically drops to 4 kHz.
Current reduction
Depending on the application conditions and the use of the
8200 motec, the rated output current may need to be
reduced on types E82MV302_4B to EMV752_4B:
8200 motec mounted on... Current reduction
...Lenze motor/geared motor, forced-ventilated Not necessary
...Lenze motor/geared motor, self-ventilated See Figure 1
...Lenze motor/geared motor, self-ventilated with fan module E82ZMV Not necessary
...not Lenze motor/geared motor Å fan module E82ZMV always required Not necessary
...the wall (wall mounting) Å fan module E82ZMV always required Not necessary
Figure 1:
Reduced rated output current in continuous operation
at 40ºC ambient temperature and 4 kHz switching
frequency/at 35ºC and 8 kHz.
I Reduced output current on the 8200 motec
I
r
Rated output current on the 8200 motec at
4 kHz/8 kHz switching frequency
f 8200 motec output frequency [Hz]
Note the torque reduction on self-ventilated motors
3)
For wall mounting/with fan module E82MV