Technical data
General data and operating conditions
4
l
15
EDSMF2181IB EN 3.0
4 Technical data
4.1 General data and operating conditions
Range Values
Order designation EMF2181IB
Communication media (system) CAN (DIN ISO 11898)
Lenze diagnostic interface
Communication media (external) Telephone analogue, 33.6 kbit/s, (V34)
Number of nodes at the CAN bus Max. 100
Baud rate l when communicating via CAN
20 kbit/s
50 kbit/s
125 kbit/s
250 kbit/s
500 kbit/s
1000kbit/s
l For communication via diagnostic interface
230.4 kbit/s
Voltage supply (external) via
separate power supply
18  30 V DC, max. 100 mA (in accordance with EN 61131−2)
Conformity and approval
Conformity
CE 2004/108/EC EMC Directive
EAC TP TC 020/2011
(TR CU 020/2011)
Electromagnetic
compatibility of technical
means
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
EAC TP TC 004/2011
(TR CU 004/2011)
On safety of low voltage
equipment
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
Operating conditions Values Deviations from the standard
Climatic conditions
Storage 1 K3 to IEC/EN 60721−3−1
− 10 ... + 60 °C
Transport 2 K3 acc. to IEC/EN 60721−3−2 − 10 ... + 70 °C
Operation 3 K3 acc. to IEC/EN 60721−3−3 0 ... + 60 °C
Enclosure of attached module IP20
Degree of pollution 2 acc. to IEC/EN 61800−5−1