Installation
Electrical installation
Voltage supply
5
l
23
EDSMF2181IB EN 3.0
5.2.4 Voltage supply
Terminal data
2181FEW001G
Terminal data
Electrical connection Plug connector with spring connection
Possible connections
rigid: 2.5 mm
2
(AWG 12)
flexible:
without wire end ferrule
2.5 mm
2
(AWG 12)
with wire end ferrule, without plastic sleeve
2.5 mm
2
(AWG 12)
with wire end ferrule, with plastic sleeve
2.5 mm
2
(AWG 12)
Stripping length
10 mm
Handling of pluggable terminal strips
( Stop!
In order to avoid damages to the pluggable terminal strips and the contacts:
ƒ The terminal strips must be wired before plugging them in!
ƒ Pluggable terminals strips that are not assigned must be plugged on as well.
Use of pluggable terminal strip with spring connection
E82ZAFX013