EasyManuals Logo
Home>Lenze>Control Unit>EMF2191IB

Lenze EMF2191IB User Manual

Lenze EMF2191IB
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Installation
Electrical installation
Operation in the standard Ethernet
5
28
EDSMF2191IB EN 2.0
5.2.4 Operation in the standard Ethernet
Note!
Operation in the standard Ethernet does not permit any real−time
communication.
The communication module can be operated in the standard Ethernet for a basic
parameter setting provided that the following applies:
1. Operation of the module in slave mode:
Network address 239
IP address: 192.168.100.<EPL address>
2. Real time operation must not be carried out.
3. No integration of a master (EPL address 240) into the standard Ethernet network.
More notes on wiring
ƒ Do not wire, if possible, more than 9nodes in succession in a network line.

Other manuals for Lenze EMF2191IB

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EMF2191IB and is the answer not in the manual?

Lenze EMF2191IB Specifications

General IconGeneral
BrandLenze
ModelEMF2191IB
CategoryControl Unit
LanguageEnglish

Related product manuals