Safety instructions
Residual hazards
2
12
Lenze BA 12.0032 4.0
2.4 Residual hazards
Protection of persons
•Riskofburnst!
Hot surfaces up to 140 °C during operation! Provide protection against contact.
High-frequency voltages can be capacitively transferred to the motor housing
through the inverter supply.
Earth motor housing carefully.
Risk of injury due to rotating shaft!
Before working on the motor ensure that the motor is at standstill.
Danger of unintentional starting or electrical shocks!
Connections must only be made when the equipment is deenergised and the
motor is at standstill.
Installed brakes are no fail-safe brakes.
Dangerous voltages at the power terminals, even if the plug is removed: residual
voltage >60 V!
Motor protection
Installed thermal detectors do not offer full protection to the machine.
If required, limit the maximum current, parameterise the inverter so that it will
be switched off after some seconds of operation with I > I
N
, especially if there is
the danger of blocking.
Installed overload protection does not prevent an overload under any
conditions.
Installed brakes are no fail-safe brakes.
The torque can be reduced due to disruptive factors that cannot be influenced,
e.g. by ingressing oil due to a defect shaft sealing ring on the A side.
Fuses are no motor protection.
Use current-dependent motor protection switches at an average operating
frequency.
Use installed thermal detectors at a high operating frequency.
Excessive torques lead to a break of the motor shaft or demagnetisation.
The maximum torques according to catalogue must not be exceeded.
Lateral forces from the motor shaft may occur.
Align shafts of motor and driving machine exactly to each other.
If deviations from normal operation occur, e.g. increased temperature, noise,
vibration, determine the cause and, if necessary, contact the manufacturer. If in
doubt, switch off the motor.
Design with plug:
Never disconnect plug when energised! Otherwise, the plug can be destroyed.
Switch off power supply and inhibit controller prior to disconnecting the plug.