Mechanical installation
Preparation
Torque plate assembly
4
43
Lenze ¯ MA 12.0014 ¯ 5.1
4.3.13 Torque plate assembly
( Stop!
Impermissible load caused by incorrect mounting:
¯ The socket of the torque plate must be mounted on both sides.
¯ When mounted, the socket must have axial clearance.
Fig. 9 Mounting of the torque plate at the base
The torque plate on the pitch circle can be mounted in various positions depending on
the pitch of the bore belt.
Fig. 10 Mounting of the pitch circle torque plate
) Note!
In the case of a knee lever design, transfer the force at right angles to the
torque plate, if possible (90°±20°).
Mounting
1. Clean the contact surfaces between the housing and torque plate.
2. Tighten the screws according to the torque specified, ( 21)