22
Commissioning
Operang Instrucons i510-Cabinet
Display code Name
Possiblesengs/
value ranges
Keypad code Informaon
P440.02 AO1 funcon Output frequency [1] Actual output frequency (resoluon: 0.1 Hz).
Frequency setpoint [2] Actual frequency setpoint (resoluon: 0.1 Hz).
Analog input 1 [3] Input signal from analog input 1 (resoluon: 0.1 %).
P440.03 AO1 min. Signal -2147483648 ... 0 ...
2147483647
Denion of the signal value that corresponds to the minimum value at analog output 1.
P440.04 AO1 max. signal -2147483648 ... 1000 ...
2147483647
Denion of the signal value that corresponds to the maximum value at analog output 1.
P450.01 Freq. preset 1 0.0 ... 20.0 ... 599.0 Hz Parameterizable frequency setpoints (preset 1).
P450.02 Freq. preset 2 0.0 ... 40.0 ... 599.0 Hz Parameterizable frequency setpoints (preset 2).
P450.03 Freq. preset 3
0.0 ... 50.0 | 60.0 ... 599.0 Hz *
Parameterizable frequency setpoints (preset 3).
P450.04 Freq. preset 4 0.0 ... 0.0 ... 599.0 Hz Parameterizable frequency setpoints (preset 4).
Defaultseng=boldprint|*Defaultsengisdevice-dependent
7.4.2 Group2:Basicseng
Display code Name Possiblesengs Keypad code Informaon
P225.00 Quick stop decelera-
on me
1.0 s Quick stop deceleraon me for “MS: Velocity mode”
• If the “Quick stop” funcon is acvated, the motor is brought to a standsll within the deceleraon me set here.
• The set deceleraon me refers to the period of deceleraon from the set maximum frequency (P211.00) to standsll. In the case of a lower
actual frequency, the actual deceleraon me is reduced accordingly.
• Seng is not eecve in operang mode P301.00 = “CiA:Velocity mode”.
7.4.3 Group 3: Motor control
Display code Name Possiblesengs Keypad code Informaon
P320.04 Rated torque 50 ... 50000 rpm General motor data.
Congure sengs as specied by the data on the motor nameplate.
Note!
Take the phase connecon implemented for the motor (star or delta conguraon) into account when entering the motor nameplate data. Only
enter data associated with the relevant conguraon.
P320.05 Rated frequency
1.0 ... 1000.0 Hz
P320.06 Rated power 0.00 ... 655.35 kW
P320.07 Rated voltage 0 ... 65535 V
P320.08 Cosine phi 0.00 ... 1.00
P327.04 Idenfy motor data 0 ... 1 1 = start automac idencaon of the motor data.
• Inverter characteriscs, motor equivalent circuit data and controller sengs are idened and set automacally.
• The motor is energized during the procedure!
P327.05 Calibrate motor data
(non-energized)
0 ... 1 1 = start automac calibraon of the motor data.
• A default inverter characterisc is loaded.
• The motor equivalent circuit data and controller sengs are calculated on the basis of the currently set rated motor data.
• The motor is not energized.