Index Name Possible settings Selection no. Information
0x2C01:004 Motor parameter: Rated speed 50 ... 1450 ... 50000 rpm
General motor data.
Carry out settings as specied by motor nameplate data.
Note!
When you enter the motor nameplate data, take into account the phase connection
implemented for the motor (star or delta connection).
Only enter the data applying to the connection type selected.
0x2C01:005 Motor parameter: Rated frequency 1.0 ... 50.0 ... 10000.0Hz
0x2C01:006 Motor parameter: Rated power
0.00 ... 0.25 ... 655.35 kW
0.00 ... 0.33 ... 878.84 hp
0x2C01:007 Motor parameter: Rated voltage 0 ... 230 ... 65535V
0x2C01:008 Motor parameter: Cosine phi 0.00 ... 0.80 ... 1.00