Thermal detectors PT1000
The thermal detector used connuously monitors the motor temperature. The temperature
informaon is transferred to the inverter using the system cable of the feedback system. This
is not a full motor protecon!
This makes it possible to determine the motor temperature in the permissible operang range
with great accuracy.
When supplying the thermal sensors with a measurement current of 1 mA, the
connecon between the temperature and the resistance measured applies.
1000
1100
1200
1300
1400
1500
1600
1700
1800
0 20 40 60 80 100 120 140 160 180
R [Ω]
T [°C]
W
R Resistance
T
W
Winding temperature
Product extensions
Temperature monitoring
Thermal detectors PT1000