Connecon via terminal box
Posion of the connecons
Posion Meaning Note
1 Power connecon
Brake connecon
PE connecon
Feedback connecon
Connecon of temperature monitoring
For the terminal box "KK1", the posion of the cable connecons
"L", "R" or "E" must be specied.
2 Blower connecon When ordering, specify the mounng posion of the terminal
box:
•
Shown here: "T"
•
"L", "R" or "B"
If required, the terminal box can be rotated step by step by 90 °
aer loosening the screws in the terminal box.
Power connecon
Bridge arrangement
Y/Δ circuit
W2
U2
V2
U1
V1
W1
L1
L2
L3
W2
U1
U2
V1
V2
W1
L1
L2
L3
Terminal box, power
Contact Name Meaning
PE PE PE conductor
U1 L1
Motor winding phaseV1 L2
W1 L3
DC brake connecon
Terminal box, DC brake
Contact Name Meaning
BD1 + Brake +
BD2 - Brake -
Product extensions
Motor connecon
Connecon via terminal box
131