Safety instructions
Residual hazards
1
l
46
EDKLCMZ3024−SPS DE/EN 4.0
1.2 Residual hazards
Protection of persons
ƒ The X2x power connector contacts can conduct hazardous voltages if the motor
starter is connected to the mains. Therefore, disconnect the motor starter before
carrying out any work on it.
ƒ The X2x power connector contacts also conduct hazardous voltages when the motor
starter is disabled. Depending on the risk analysis of the machine/system, you may
have to take additional protective measures.
ƒ Operation at ambient temperatures > 40°C:
The operating temperature of the motor starter housing is > 60°C.
Depending upon the risk analysis of the machine/system, you may have to use
additional protective covers.
Motor protection
ƒ The connected motor can overheat if
Motors are operated on the motor starter that do not feature temperature
monitoring with PTC thermistor (PTC) or thermal contact (NC contact)
Temperature monitoring with PTC thermistor (PTC) or thermal contact (NC
contact) is not connected to the motor starter
Temperature monitoring is not activated (C0119)
The set rated motor current for I
2
t monitoring is not adjusted to the motor (C0120)
–I
2
t monitoring is switched off (C0121)