DISASSEMBLY/REASSEMBLY
Clean the filtering element with air blast. Air must be blown
from inside to outside the cartridge at a distance of at least
15 cm from the paper.
Lightly and repeatedly tap the element on a hard surface to
eliminate all excess dirt.
Dry air cleaner for 15LD 400-440
Open air cleaner (fig. 4).
Unscrew the wing nut 1 (fig. 4a) and remove the filter element (fig.
5).
Check the rubber seal is undamaged A (fig. 5a)
Clean the filtering element with air blast.
If the filtering element has been already cleaned other times, or if it
is irreparably clogged, throw it away and replace .
Refit the air filter and make sure the seal A is properly inserted, then
tighten the wing nut 1.
Make sure that the filter is mounted in the correct way
otherwise dust and other impurities could ilfiltrate into the
intake ducts.
Prefilter for dry air filter
Remove and clean the pre-filter if clogged.