Operating Manual Smart Weather Sensor
136 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
19.8.6.4 Continuous Measurement 0R0 Format
Command identifier: PC
Parameter: none
Command example:
Command *0100PC<CR><LF>
After this command the device will start to transmit the result message as defined in for the
single measurement automatically with the interval defined by the transmission interval
command (see 19.8.7.1) or set by the UMB Config Tool.
The default interval is 60 seconds, minimum allowed interval is 10sec, maximum interval is
43200sec (=12h).
The continuous mode will be stored in the E2PROM of the device, so that after a reset the
device will continue to transmit automatically.
The continuous mode is terminated by a Single Measurement Command (19.8.6.1,
19.8.6.3).