14.8.2 Checking the Electrolyte Level
Check the electrolyte level and specific gravity at intervals of three
months. Check all the six cells for proper electrolyte levels. If the
level is below the lower marker, add distilled water until the level
reaches the upper marker.
Adding distilled water;
Remove the vent plugs
Add distilled water to all the cells that require the fluid and
secure the plugs properly
14.9 Wiper Blades
Lift the wiper arm from its position. Expose the blade lip for
inspection. Clean the wiper blade lips with water applied with a soft
sponge. If the wiper blade is not wiping the glass satisfactorily or is
worn-out, cut, cracked or bulging get it replaced at an Authorized
Mahindra Dealer.
14.9.1 Changing the Wiper Blade
1. Lift the arm and position the wiper blade at right angles to
the wiper arm
2. Press the retaining clip in the opposite direction, disengage
the wiper blade and pull it off the arm
3. Hold the end of the rubber and pull until the tabs are free of
the metal support
4. Carefully insert the new blade rubber. Then install the blade
assembly in the reverse order of removal
MAINTENANCE

Table of Contents

Other manuals for Mahindra XUV 500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mahindra XUV 500 and is the answer not in the manual?

Mahindra XUV 500 Specifications

General IconGeneral
BrandMahindra
ModelXUV 500
CategoryAutomobile
LanguageEnglish

Related product manuals