Commissioning and operation
31
Ship-specific alarms
There is the possibility to connect 11 ship-specific alarms or warnings and to generate
these using software. The text of the alarms or warnings is entered by the shipyard.
In the event of an alarm, the corresponding measurement point text appears on the
alarm page; the program switches automatically into the alarm menu. In the case of
warnings, the program does not switch automatically into the alarm menu.
4. Engine room panel MMDS-EP
Motordrehzahl 1835 upm
Motoroeltemperatur 120 C
Ladelufttemperatur 64 C
Kuehlwassertemp. 83 C
Motoroeldruck 4.3 bar
M
1
A
3
ALARMS
Men
PAGE RESET
Prg
Engine run
System Fail.
Alarm
MAN MARINE DIESEL
TYP MMDS–EP
TEST
51.27720–7018
The functions of the keys and of the LCD displays are the same as those on the
MMDS-LC (see operating instructions for MMDS-LC).
Differences to MMDS-LC:
D no ship-specific alarms can be programmed
D additional: –Ignition
–Pre-glow plug
Note on pre-glow plug:
The pre-glow plug is not active in the in-line 6-cylinder engine (D 2876 LE401
/404), as this engine is not equipped with a pre-glow system.
On V-engines, pre-glow can be fitted as an option. In ignition position “I”, the
lamp lights up. Wait until the lamp begins to flash, then start.