Part Number STH025 11/16 75
ICE BIN LEVEL SENSOR
Ice bin sensor is an optional accessory that allows the ice
level in the bin to be set to one of three different levels.
The bin level can be set seasonally to match usage, which
results in lower energy costs and fresher ice.
1. From the Set-Up menu, use the Down arrow to
highlight Ice Bin Sensor.
2. Press the Checkmark. On this screen, you can
choose to set the ice level to Low, Medium or
High by highlighting your choice and pressing the
Checkmark. Selecting one will deselect the other.
When the check reflects your preference, use the Down
arrow to navigate to Exit and press the Checkmark. The
display will return to the Set-Up menu.
USB SETUP
Refer to “Upgrading Firmware with a Flash Drive” and
“Exporting Data to a Flash Drive” for more information
on this setting. Flash drives must be correctly sized and
formatted - 2 gigabytes or smaller, Fat 32 file system, 512
allocation units - Refer to page 95 for full specification
and formatting details.
FACTORY DEFAULTS
The entire setup can be reset to factory defaults listed on
page 69.
1. From the Set-Up menu, use the Down arrow to
highlight Fact Default.
2. Press the Checkmark two times to reset the ice
machine. The display will return to the Set-Up menu.