102 Part Number: 000015431 Rev01 5/19
Installation/Visual Inspection Checklist
Inadequate Clearances
• Check all clearances on sides, back and top.
See “Clearance Requirements” on page 29
Ice machine is not level
• Level the ice machine
Condenser is dirty
• Clean the condenser
Water filtration is plugged (if used)
• Install a new water filter
Water drains are not run separately and/or are not
vented
• Run and vent drains according to the Installation
Manual
• Floor drain must have an air gap
• Install condensation drain in the ice machine base
Line set is improperly installed
• Reinstall according to the Installation, Operation and
Maintenance Manual
Lineset is the incorrect size
• Refer to Installation, Operation and Maintenance
Manual
See “Water Supply and Drains” on page 32