Part Number: 000015431 Rev01 5/19 27
ICE BEVERAGE MODELS
• Ice/Beverage Ice Machines require that a proper ice
level be maintained when installed on a dispenser. Ice
Beverage machines ship with a ice level management
sensor pre-installed.
• The ice machine head is installed with the electrical
inlet, water supply inlet, refrigeration tubing and water
drain entering from the back of the ice machine.
• The ice machine head section contains a service loop
that must remain installed between the ice machine
head section and line set. Sufficient tubing length must
be available to allow 180° rotation of the ice machine.
• Maintain a 3" space between the back of the ice
machine and the back of the dispenser to allow room
for the refrigeration line set service loop.
• The water inlet and electrical connection must contain
a service loop to allow future service and maintenance
access.
• The drain line must contain a union or other suitable
means of disconnection at the ice machine head
section.
• The location must be free of airborne and other
contaminants.
• The air temperature must be at least 35°F (1.6°C), but
must not exceed 110°F (43°C).
• The location must not be near heat-generating
equipment or in direct sunlight.