Part Number: 000015431 Rev01 5/19 45
PARTS REMOVAL FOR CLEANING/SANITIZING
Single Evaporator Ice Machines
B
C
D
E
A
A. Remove the water curtain
Gently flex the curtain in the center and remove it
from the right side.
Slide the left pin out.
B. Remove the water trough
Depress tabs on right and left side of the water trough.
Allow front of water trough to drop as you pull forward
to disengage the rear pins.
C. Remove the water level probe
Pull the water level probe straight down to disengage.
Lower the water level probe until the wiring connector
is visible.
Disconnect the wire lead from the water level probe.
Remove the water level probe from the ice machine.