SUCTION ACCUMULATOR OPERATION
Liquid refrigerant collects in the suction accumulator
during the harvest cycle and is removed during the
freeze cycle. The liquid refrigerant is returned to the
compressor through a screen and orifice in the suction
accumulator J tube. Passing the liquid through the
orifice causes a pressure drop; the liquid flashes to a
vapor and creates a refrigeration affect. It is normal to
see frost on the accumulator, suction line and
compressor suction port in the freeze cycle. The
suction accumulator empties within the first 5 minutes
of the freeze cycle. When the refrigeration affect ends
(liquid refrigerant has been removed), the suction line
between the accumulator and compressor will
increase in temperature. The suction line temperature
increases 20 plus degrees within 2 minutes after the
liquid has been removed.
The time needed to remove the liquid refrigerant will
vary with the ambient temperature and the length of
the harvest cycle. Higher ambient temperatures =
shorter harvest cycles, faster removal of liquid
refrigerant from the accumulator and greater suction
line temperature increases.
1
Minute
2
Minutes
3
Minutes
4
Minutes
5
Minutes
6
Minutes
7
Minutes
8
Minutes
Temperature Increases
20+ºF (18+ºC)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SY1874C and is the answer not in the manual?

Manitowoc QuietQube SY1874C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SY1874C
CategoryIce Maker
LanguageEnglish

Related product manuals