38 Part Number 80-1505-3 6/11
WATER COOLED CONDENSER WATER SUPPLY
AND DRAINS
Water Cooled Condenser Lines
Follow these guidelines to install water lines:
Contact your distributor if your water pressure is
greater than 150 psig (1034 kPA). A special order
condensing unit is available that allows water
pressure up to 350 psig (2413 kPA).
Install a shutoff valve (inlet and outlet on cooling
tower or closed loop circuits) to allow isolation of
the water system.
Water entering the condenser must not exceed
90°F (32.2°C).
Water flow through the condenser must not
exceed 5 gallons (19 liters) per minute.
Allow for a pressure drop of 8 psig (55 kPA)
between the condenser water inlet and outlet.
Water exiting the condenser must not exceed
110°F (43.3°C).
Do not connect to the potable water filter system.
Condensing Unit Drain Connections
The condensing unit drain is provided to remove any
condensate produced by the suction accumulator.
Condensate amounts will vary depending on
temperature and humidity.
The condensing unit must be level front to back
and side to side to allow the condensate to drain.
Drain lines must have a 1.5-inch drop per 5 feet of
run (2.5 cm per meter), and must not create traps.
Drain termination must meet applicable costs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SY1874C and is the answer not in the manual?

Manitowoc QuietQube SY1874C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SY1874C
CategoryIce Maker
LanguageEnglish

Related product manuals