242 Part Number 80-1505-3 6/11
SY0684C/CVD0685 SERIES REMOTE AIR COOLED
NOTE: These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
8.2-9.5 9.0-10.4 9.7-11.2
.75-2.5
90/32 8.9-10.2 9.7-11.2 10.5-12.1
100/38 9.5-11.0 10.5-12.1 11.5-13.2
110/43 10.5-12.1 11.7-13.5 12.9-14.8
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10 70/21 90/32
-20 to 70/
-29 to 21
680 630 590
90/32
640 590 550
100/38
600 550 510
110/43
550 500 460
1
Based on average ice slab weight of 4.6-5.2 lb.
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
-20 to 50/
-29 to 10
200-250 44-26 180-210 65-85
70/21 235-255 50-28 185-210 65-90
80/27 245-275 50-28 190-210 75-100
90/32 250-290 52-30 195-215 75-105
100/38 270-320 52-31 210-240 80-110
110/43 300-360 60-32 215-260 85-115