Part Number 80-1505-3 6/11 75
Step 2 Set the toggle switch to the OFF position after
ice falls from the evaporator at the end of a Harvest
cycle. Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
Step 3 Remove all ice from the bin.
Step 4 Place the toggle switch in the CLEAN
position. The water will flow through the water dump
valve and down the drain. Wait until the water trough
refills and water flows over the evaporator, then add
the proper amount of ice machine cleaner.
Step 5 Wait until the clean cycle is complete
(approximately *35 minutes). then place the toggle
switch in the OFF position and disconnect power to
the ice machine (and dispenser when used).
NOTE: *S307C Only - 80 minutes.
Step 6 Remove parts for cleaning.
Please refer to the proper parts removal for your
ice machine.
S600C/S680C/S850C/S1000C/S1200C - page 76.
S1470C/S1870C/S2070C/S2170C - page 77.
S3070C - page 80.
!
Caution
Never use anything to force ice from the
evaporator. Damage may result.
Model Amount of Cleaner
S0600C/S0680C/S0800C
S1000C/S1200C
5 ounces (150 ml)
S1470C/S1870C/
S2070C/S2170C
9 ounces (270 ml)
S3070C 16 ounces (475 ml)
!
Warning
Disconnect the electric power to the ice machine
at the electric service switch box.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SY1874C and is the answer not in the manual?

Manitowoc QuietQube SY1874C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SY1874C
CategoryIce Maker
LanguageEnglish

Related product manuals