80 Part Number 80-1505-3 6/11
S3070C
A.Remove front evaporator shield.
• Remove four quarter turn connectors
• Remove splash shield
B.Remove Splash Shields.
NOTE: Each evaporator has a splash shield that must
be removed - total of four splash shields.
• Grasp the top center of splash shields.
• Lift up and then out.
C. Remove ice thickness probe.
• Compress the hinge pin on the top of the ice
thickness probe.
• Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be
cleaned at this point without complete removal. If
complete removal is desired, disconnect the ice
thickness control wiring from the control board.
D. Remove the water pump assembly.
• Disconnect the vinyl distribution tube from both
water pumps.
• Disconnect the water pump and water level probe
electrical connections.
• After the wires are disconnected remove the two
thumbscrews and lift the water pump assembly out
of the ice machine.
E. Remove the water trough.
• Pull forward on the water trough to remove.
NOTE: Proceed to page 82, Step 7.