EasyManuals Logo
Home>Manitowoc>Ice Maker>QuietQube SY1874C

Manitowoc QuietQube SY1874C User Manual

Manitowoc QuietQube SY1874C
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
80 Part Number 80-1505-3 6/11
S3070C
A.Remove front evaporator shield.
Remove four quarter turn connectors
Remove splash shield
B.Remove Splash Shields.
NOTE: Each evaporator has a splash shield that must
be removed - total of four splash shields.
Grasp the top center of splash shields.
Lift up and then out.
C. Remove ice thickness probe.
Compress the hinge pin on the top of the ice
thickness probe.
Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be
cleaned at this point without complete removal. If
complete removal is desired, disconnect the ice
thickness control wiring from the control board.
D. Remove the water pump assembly.
Disconnect the vinyl distribution tube from both
water pumps.
Disconnect the water pump and water level probe
electrical connections.
After the wires are disconnected remove the two
thumbscrews and lift the water pump assembly out
of the ice machine.
E. Remove the water trough.
Pull forward on the water trough to remove.
NOTE: Proceed to page 82, Step 7.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SY1874C and is the answer not in the manual?

Manitowoc QuietQube SY1874C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SY1874C
CategoryIce Maker
LanguageEnglish

Related product manuals