34 Part Number 000014797 Rev02 05/18
Remove Parts for Cleaning
n
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
1. Remove the Harvest Float Switch and Ice Thickness
Float Switch
Pull forward on the bottom of the bracket until
clear of the tab, then slide bracket upward to
remove the bracket and float as an assembly. At
this point, the float switches can easily be cleaned.
If complete removal is desired, follow the wires
to the bulkhead grommet (exit point) in the back
wall. Pull the wire connector through the bulkhead
grommet, then disconnect the wire leads from the
connector.
NOTE: The wire from the top grommet goes to the ice
thickness float switch (front switch). The wire from the
bottom grommet goes to the Harvest float switch (side
switch).
Important
Reversing the mounting location of the ice thickness and
the harvest floats will result in a safety limit 2 failure.
The ice thickness float must be mounted to the front
of the water trough and the electrical connection must
be in the top bulkhead grommet.
The harvest float must be mounted to the side of the
water trough and the electrical connection must be in
the bottom bulkhead grommet.
The wire connectors for each float are different and
will not allow incorrect electrical bulkhead connection.

Table of Contents

Other manuals for Manitowoc URF0140A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc URF0140A and is the answer not in the manual?

Manitowoc URF0140A Specifications

General IconGeneral
BrandManitowoc
ModelURF0140A
CategoryIce Maker
LanguageEnglish

Related product manuals