88 Part Number 000014797 Rev02 05/18
ICE THICKNESS CHECK
After a harvest cycle, inspect the ice cubes in the ice
storage bin. The ice thickness probe is set to maintain an
ice bridge of 1/8” (3.2 mm). If an adjustment is needed,
follow the steps below.
1. Turn the ice thickness probe adjustment screw
clockwise for a thicker ice bridge, or counterclockwise
for a thinner ice bridge.
2. Make sure the ice thickness probe wire and bracket
does not restrict movement of the probe.
Adjustment Screw