168 Part Number 000014797 Rev02 05/18
ANALYZING ICE FORMATION PATTERN
Evaporator ice formation pattern analysis is helpful in ice
machine diagnostics.
Analyzing the ice formation pattern alone cannot diagnose
an ice machine malfunction. However, when this analysis
is used along with Manitowoc’s Refrigeration System
Operational Analysis Table, it can help diagnose an ice
machine malfunction.
OUTLET
INLET
Normal Ice Formation
Ice forms across the entire evaporator surface.
At the beginning of the Freeze cycle, it may appear that
more ice is forming on the inlet of the evaporator than at
the outlet. At the end of the Freeze cycle, ice formation
at the outlet will be close to, or just a bit thinner than,
ice formation at the inlet. The dimples in the cubes at the
outlet of the evaporator may be more pronounced than
those at the inlet. This is normal.
If ice forms uniformly across the evaporator surface, but
does not do so in the proper amount of time, this is still
considered a normal ice fill pattern.

Table of Contents

Other manuals for Manitowoc UYF0240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc UYF0240A and is the answer not in the manual?

Manitowoc UYF0240A Specifications

General IconGeneral
BrandManitowoc
ModelUYF0240A
CategoryIce Maker
LanguageEnglish

Related product manuals