22 Part Number 000014797 Rev02 05/18
Ice Machine Clearance Requirements
Self-contained
Air-cooled
Self-contained
Water-cooled
Top/Sides 5" (127 mm)* 5" (127 mm)*
Back 5" (127 mm)* 5" (127 mm)*
*The ice machine may be built into a cabinet.
Ice Machine Heat of Rejection
Series
Ice Machine
Heat of Rejection*
Air Conditioning** Peak
UDE065 1600 2350
UDE080 1750 2600
U0140/UF0140 2400 2900
U0190/UF0190 2200 2600
U0240/UF0240 2800 3300
U0310/UF0310 3800 6000
* B.T.U./Hour
** Because the heat of rejection varies during the ice
making cycle, the figure shown is an average.
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing air
conditioning equipment where self-contained air-cooled
ice machines are installed.