Part Number 000014797 Rev02 05/18 41
CLEANING THE CONDENSER
General
n
Warning
Disconnect electric power to the ice machine head
section and the remote condensing unit at the electric
service switches before cleaning the condenser.
A dirty condenser restricts airflow, resulting in excessively
high operating temperatures. This reduces ice production
and shortens component life.
Clean the condenser at least every six months.
n
Warning
The condenser fins are sharp. Use care when cleaning
them.
Shine a flashlight through the condenser to check for
dirt between the fins.
Blow compressed air or rinse with water from the
inside out (opposite direction of airflow).
NOTE: Cleaning the condenser will require the removal of
the bin on some models.