92 Part Number 000014797 Rev02 05/18
CONTROL BOARD TEST MODE
NOTE: The ice damper/bin switch can be open or closed
and does not effect the operation of the test mode.
To enter the test mode press and hold the test switch on
the control board for 3 seconds. Refer to “UF0310 Wiring
Diagram 1Ph Air/Water
Self Contained Air & Water-cooled” on page 241. The
control board test mode performs the following functions
for a 2 minute time period:
• Energizes all control board relays
• Energizes all control board lights
• Energizes all touch pad control lights
After 2 minutes the control board will automatically
initiate and complete one ice making cycle, then stop.
Canceling a test cycle:
To cancel a test cycle press the test button a second time.
Restarting a test cycle:
The test cycle will restart each time the test button is
pressed for a 3 second time period.
OPERATING ICE MACHINE WITH BIN AND TOUCH PAD
REMOVED
The ice machine is designed to allow diagnostic procedures
to be performed with the bin removed. The touch pad is
attached to the bin and is disconnected during the removal
process. Use the control board test mode to operate the
ice machine without connecting the touch pad. Refer to
“UF0310 Wiring Diagram 1Ph Air/Water
Self Contained Air & Water-cooled” on page 241
NOTE: Software versions before 2.70 operate for 1 cycle
in test mode. Software versions after 2.70 operate for 500
cycles in test mode.