5. Maintenance
45
5.1 Replacing The Batteries
WARNING
To avoid electric shock, make sure that the
test leads have been clearly move away from
the circuit under measurement before
opening the battery cover of the meter.
5.1.1 If the sign “ ” appears, it means that the
batteries should be replaced.
5.1.2 Loosen the fixing screw of the battery cover and
remove it.
5.1.3 Replace the exhausted batteries with new ones.
5.1.4 Put the battery cover back and fix it again to its
origin form.
Note:
Do not reverse the poles of the batteries.
V
OFF
Ω
OFF
A
A
INRUSH
DIGITALCLAMP
COM
INPUT
MAX600A
CAT III 600V
MAX
MIN
RAN
HOLD
B.L
Hz/%
SEL
Hz
AUTO
MAN U
MAX MIN
ZER O
°C°F%
μmVA
nμmF
MkΩ
INR USH
TRM S
5.2 Replacing Test Leads
WARNING
The replacement must be test leads in good
working condition with the same or
equivalent rating: 1000V 10A.
A test lead must be replaced if the insulation layer has
been damaged, e.g. the wire inside is exposed.
6. Accessories
Test Leads: Electric Ratings 1000V 10A
1 pair (set)1)
1.5V AAA Battery
3 piece
3)
Operating Manual
1 copy
2)