TEMPERATURE
[ 1 ] If the temperature being measured is out of the range of 32 to
1832ºF (0 to 1000ºC) the display may show a reading, but the
measurement error may be large or the thermocouple may be
damaged.
1.
2.
3.
Use a K type thermocouple.
Accuracy does not include error of the thermocouple
probe.
Accuracy specification assumes ambient temperature
is stable to ±1.8ºF (1ºC). For ambient temperature
changes of ±9ºF (5ºC), rated accuracy applies after 1
hour.
Note:
RANGE
32 to 752ºF (0 to 385ºC)
1ºF (0.6ºC)
±(1.0% + 5)
±(2.5% + 10)
——— [ 1 ]
752 to 1832ºF (385 to
1000ºC)
RESOLUTION ACCURACY
OVERRANGE
INDICATION
BATTERY TEST
RANGE
1.5 V about 20 mA
about 5 mA
about 4 mA
9 V
12 V
DESCRIPTION TEST CURRENT
The working voltage of the battery will
be shown on the display so that the
quality of the battery can be judged.
12