EasyManuals Logo
Home>MasterPower>Inverter>OMEGA LV Series

MasterPower OMEGA LV Series User Manual

MasterPower OMEGA LV Series
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
28
SPECIFICATIONS
MODEL
1KW
2KW
3KW
4KW
5KW
2.4KW
RATED OUPUT POWER
1000 W
2000 W
3000W
4000W
5000W
2400W
PV INPUT (DC)
Max. PV Power
1000W
2000W
4000W
4000W
6000W
2000W
Max. PV Array Open Circuit
Voltage
145 VDC
145 VDC
145 VDC
145 VDC
145 VDC
145 VDC
MPPT Range @ Operating Voltage
15 VDC~115 VDC
30 VDC~115 VDC
60 VDC~115 VDC
30 VDC~115 VDC
Number of MPP Tracker
1
1
1
1
2
1
GRID-TIE OPERATION
GRID OUTPUT (AC)
Nominal Output Voltage
220/230/240 VAC
101/110/120
VAC
Feed-in Grid Voltage Range
195.5~253 VAC @India regulation
184 ~ 264.5 VAC @Germany regulation
184~264.5VAC @ South America regulation
89~111 VAC @
101 VAC output
97~121 VAC @
110 VAC output
106~132 VAC @
120 VAC output
Feed-in Grid Frequency Range
49~51Hz @India regulation
47.5~51.5Hz @Germany regulation
57~62Hz @ South America regulation
47.5~51.5Hz @
50Hz
57.5~61.5Hz @
60Hz
Nominal Output Current
4.3A
8.7A
13A
17.4A
21.7A
29.7A @ 101Vac
27.2A @ 110Vac
25.0A @ 120Vac
Power Factor Range
>0.99
Maximum Conversion Efficiency
(DC/AC)
90%
85%
OFF-GRID, HYBRID OPERATION
GRID INPUT
Acceptable Input Voltage Range
90 - 280 VAC or 170 - 280 VAC
65 - 140 VAC or
85 140 VAC
Frequency Range
50 Hz/60 Hz (Auto sensing)
Rating of AC Transfer Relay
30A
40A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage
220/230/240 VAC
101/110/120
VAC
Output Waveform
Pure Sine Wave
Efficiency (DC to AC)
93%
90%
BATTERY & CHARGER
Nominal DC Voltage
12 VDC
24 VDC
48 VDC
48 VDC
48 VDC
24 VDC
Maximum Charging Current (from
Grid)
60A
Maximum Charging Current (from
PV)
80A
80A
80A
80A
120A
80 A
Maximum Charging Current
140A
140A
140A
140A
180A
140 A
GENERAL
Dimension, D X W X H (mm)
440 x 300 x 100
440 x 300 x 100
120 x 295 x 468
120 x 295 x 468
190 x 295 x 483
120 x 295 x 468
Net Weight (kgs)
8
8
11
11
16
11
INTERFACE
Parallel-able
N/A
N/A
Yes
Yes
Yes
Yes
External Safety Box (Optional)
Yes
Communication
USB or RS232/Dry-Contact
ENVIRONMENT
Humidity
0 ~ 90% RH (No condensing)
Operating Temperature
0 to 50°C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MasterPower OMEGA LV Series and is the answer not in the manual?

MasterPower OMEGA LV Series Specifications

General IconGeneral
BrandMasterPower
ModelOMEGA LV Series
CategoryInverter
LanguageEnglish

Related product manuals