Read this entire manual before attempting to operate or service the MAXBlend2. Attempting to
operate the MAXBlend2 without fully understanding its features and functions may result in unsafe
operating conditions.
CLASSIFICATION
Protection class:....................................................... II, Type B
Protection against water: ....................................................IPX1
Mode of operation:....................................................Continuous
Sterilization: ......................................................See section 6.0
Safety of application in the presence of a flammable anesthetic mixture:.........See section 9.4
Power specification: ................................7.5V(MAX) 1.9W/250mA(MAX)
CAUTION: Federal law restricts this device to sale by or on the order of a medical professional.
Product Disposal Instructions:
The sensor, batteries, and circuit board are not suitable for regular trash disposal. Return
sensor to Maxtec for proper disposal or dispose according to local guidelines. Follow local
guidelines for disposal of other components.
WARRANTY
The MAXBlend2 is designed for air/oxygen delivery. Under normal operating conditions, Maxtec
warrants the MAXBlend2 to be free from defects of workmanship or materials for a period of two years
from the date of receipt from Maxtec, provided that the unit is properly operated and maintained in
accordance with Maxtec’s operating instructions. Based on Maxtec’s product evaluation, Maxtec's sole
obligation under the foregoing warranty is limited to making replacements, repairs, or issuing credit for
equipment found to be defective. This warranty extends only to the buyer purchasing the equipment
directly from Maxtec or through Maxtec's designated distributors and agents as new equipment.
Maxtec warrants the MAX-550E oxygen sensor in the MAXBlend2 to be free from defects in material
and workmanship for a period of two years from Maxtec's date of shipment in a MAXBlend2 unit.
Should a sensor fail prematurely, the replacement sensor is warranted for the remainder of the original
sensor warranty period. Routine maintenance items, such as batteries, are excluded from warranty.
Maxtec and any other subsidiaries shall not be liable to the purchaser or other persons for incidental
or consequential damages or equipment that has been subject to abuse, misuse, mis-application,
alteration, negligence or accident. THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE.
EC REP
QNET BV
Kantstraat 19
NL-5076 NP Haaren
The Netherlands
9700630
Conforms to AAMI STD ES60601-1, ISO STD 80601-2-55,
IEC STDS 60601-1-6, 60601-1-8 & 62366
Certified to CSA STD C22.2 No. 60601-1