Service Manual_2018-V1.0
35
Step 1: Check whether the terminal CN12 of main
control board is well stuck, pull out the terminal and
re-stick it in place and check if there is any foreign
matter on the terminal
Step 2: Check whether the terminal of ice maker is well
Variable frequency driver board fault analysis
Variable frequency driver board LED
Blink once: light 1S, extinguish 1S
Blink once: light 0.5S, extinguish 1.5S
Blink twice: light 0.5S, extinguish 0.5S, interval
time(extinguish) is 1.5 second
Blink four times: light 0.5S, extinguish 0.5S, interval
time(extinguish) is 1.5 second
Blink eight times: light 0.5S, extinguish 0.5S, interval
time(extinguish) is 1.5 second
Blink sixteen times: light 0.5S, extinguish 0.5S, interval
time(extinguish) is 1.5 second
9.6 Defrosting function
1)Defrost the freezing chamber as per the accumulative operation time of the Compressor
2)After running 6 hours continuously, enter defrost mode, if defrost mode has been entered, it will not
enter.