EasyManuals Logo
Home>Minelab>Metal Detector>E-Trac

Minelab E-Trac User Manual

Minelab E-Trac
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
62
63
Audio Menu
To change the Response:
1 Press the Menu button
2 Scroll across to Audio (using the Right or
Left Navigation button)
3 Scroll down to Response (using the Down
Navigation button)
4 Press either the Left or Right Navigation
button to change the Response to the
desired setting
5 Press the Detect button to exit the Menu
and resume detecting
Note: Even though you can still select Pitch
Hold when the No. of Tones is set to 1,
it will not have any effect on the target
audio response.
Smooth
This setting is similar to Long, with the addition of
some filtering of the audio tone response. Smooth
reduces the variability of the pitch, offering a
smoother continuous sound.
Pitch Hold
When Pitch Hold is selected, the normal rise-and-
fall target signal is replaced with a continuous tonal
response. The tone emitted is the strongest signal
coming from the target, and will continue until a new
target is detected.
Response
Range: Normal, Long,
Smooth and Pitch Hold
Factory Preset: Normal
The Response setting changes the way target
signals sound upon detection. Response can
improve your ability to identify certain targets
in different conditions, such as high trash,
mineralised ground and beaches.
As the coil is swept over a target, the target
signal rises. At the peak of the target signal,
audio is emitted. Minelab recommends rst
learning how to operate the detector in the
Factory Preset ‘Normal audio Response.
After becoming familiar with the way E-Trac
interprets various targets, it is recommended
you experiment with the Response settings
listed right. Each Response will suit certain
detecting conditions. You will soon develop
your own preference by experimentation.
Normal
Emits a short response to targets (almost a ‘beep’).
Normal is recommended for general detecting
conditions. It allows the greatest differentiation
between the ground and a target, but has the
potential to miss small targets in areas littered with
objects producing target responses.
Long
Offers an almost continuous audio response. This
setting is ideal for responding to several targets close
together. It is recommended for the experienced user,
who can pick the tonal differences between various
targets. Long can be a little confusing for the
beginner but has the potential to offer greater
accuracy and depth.
Detection Start
Detection End
Peak Target Signal
Threshold Threshold
Threshold Threshold
Threshold Threshold
Threshold Threshold
Threshold Threshold
Blanking
Normal lasts until the target signal drops, then audio
blanks bringing a crisp end to the detection.
Pitch Hold changes the Threshold to the highest
pitched tone produced during the detection.
Long lasts until the end of detection.
There is no blanking at the end of detection.
Smooth lasts until the end of detection.
There is no blanking at the end of detection.
Blanking
Pitch
Time
Time
Time
Time
Time
Pitch Pitch Pitch Signal Strength
Response
Response
Response
Response

Other manuals for Minelab E-Trac

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minelab E-Trac and is the answer not in the manual?

Minelab E-Trac Specifications

General IconGeneral
Transmission TechnologyFull Band Spectrum (FBS) Multifrequency Technology
Microprocessor32bit, 48MHz microprocessor – fast and powerful
CoilUltra-lightweight 11” Double D (DD) waterproof coil
ConnectivityUSB connector for communication with Personal Computer
SoftwareIntuitive User Interface; Fast Target processing; Multi-language functionality
QuickMask™Fast and Easy adjustment of Ferrous and Conductivity Discrimination
User Modes4 Minelab Modes and 4 My Modes
Depth GaugeAccurate Gauge active in Normal detecting and Pinpoint mode
PinpointNon-motion with modulated audio and visual Crosshair on LCD, 2 Modes – Normal and Sizing
Discrimination2 Dimensional Smartfind™ Discrimination
Target Identification2 Dimensional Smartfind™ Size / Conductivity and Ferrous characteristics Conductivity 1-50, Ferrous 1-35
Sensitivity AdjustmentFully Automatic; adjustable to be more aggressive or conservative, Manual Setting 1-30
Sensitivity GaugeAuto Level, Manual Level, Suggested Level
ThresholdFine adjustment level from 1-50
Recovery SpeedSelectable Fast & Deep
Trash DensityLow for areas with isolated targets or High, for areas with more trash
Noise CancelAutomatic & Manual selection of 11 channels
Audio Response4 Settings: Normal, Long, Smooth, Pitch Hold
Tone ID Number of Tones1, 2, 4 and Multi-tone; customizable for Conductivity or Ferrous response
Tone ID Variability30 adjustable steps for better Target Identification
HeadphoneInput ¼” 100Ω Stereo Jack
Ground Balance ModesAuto Ground Compensation - Advanced Digital Filtering
Ground SettingsNeutral for most ground conditions, Difficult for more mineralized soils
Batteries1600 mAh NiMH or Alkaline batteries
Low Battery Audio AlarmAudio and visual indication
Visual DisplayLarge 3.4” (8.65cm) greyscale LCD panel with Contrast adjustment and Backlight
PatentsUS 4890064; US 5537041; US 5506506