70
71
Expert Menu
The Expert Menu contains some of E-Tracs
more advanced settings and functions.
While the settings and functions within the
Expert Menu will allow you to get the most
out of your E-Trac, Minelab recommends
that you become familiar with the other
settings and functions of the detector before
experimenting with these.
Recovery Deep
Range: On–O
Factory Preset: O
This setting affects only weak target signals,
enhancing identification of deep targets.
This setting should be selected in relatively
uncluttered areas where deep targets are
anticipated. Strong signals are unaffected.
In the deep setting there will be a slightly
slower reaction in target signal and Target ID
due to the extra filtering that is employed in
the processing of the target characteristics.
To turn Recover Deep On or Off:
1 Press the Menu button
2 Scroll across to Expert (using the Right or
Left Navigation button)
3 Scroll down to Recovery Deep (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to turn Recovery Deep On or O
5 Press the Detect button to exit the Menu
and resume detecting
In the example shown, using Recovery Fast
will provide two distinct target IDs in each
direction, whereas when Recovery Fast is O
the ID will be more variable and may not
resemble either of the targets.
Note: Minelab recommends turning Recovery
Fast On when Trash Density (pp. 72–3) is set to
High
To turn Recover Fast On or Off:
1 Press the Menu button
2 Scroll across to Expert (using the Right or
Left Navigation button)
3 Scroll down to Recovery Fast (using the
Down Navigation button)
4 Press either the Left or Right Navigation
button to turn Recovery Fast On or O
5 Press the Detect button to exit the Menu
and resume detecting.
Recovery Fast
Range: On–O
Factory Preset: O
By selecting this setting, the detector
will react faster to target signals, but the
discrimination and Target ID may be slightly
more erratic. Use Fast in areas littered with
objects, where a desired target could be
hiding next to unwanted objects.
For example, if there are two targets very
close together that cause a single detection,
the filtering that is usually employed
when Recovery Fast is Off may cause a
contamination’ of the Target IDs,
as shown below.
Recovery Fast On
Volume
CoinNail
Time
Recovery Fast Off
Volume
Time
CoinNail
Recovery Deep and Recovery Fast
The Recovery Deep and Recovery Fast
settings allow you to select the way the
discrimination process works. Recovery
settings affect both the detector’s audio and
display response to target characteristics.
With Recovery Fast On, the usual filtering
is bypassed and this can provide a more
accurate ID of the second target due to the
reduced blending of target signals. However,
as a consequence of removing the filtering
the Target IDs may be slightly more erratic.

Other manuals for Minelab E-Trac

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minelab E-Trac and is the answer not in the manual?

Minelab E-Trac Specifications

General IconGeneral
Transmission TechnologyFull Band Spectrum (FBS) Multifrequency Technology
Microprocessor32bit, 48MHz microprocessor – fast and powerful
CoilUltra-lightweight 11” Double D (DD) waterproof coil
ConnectivityUSB connector for communication with Personal Computer
SoftwareIntuitive User Interface; Fast Target processing; Multi-language functionality
QuickMask™Fast and Easy adjustment of Ferrous and Conductivity Discrimination
User Modes4 Minelab Modes and 4 My Modes
Depth GaugeAccurate Gauge active in Normal detecting and Pinpoint mode
PinpointNon-motion with modulated audio and visual Crosshair on LCD, 2 Modes – Normal and Sizing
Discrimination2 Dimensional Smartfind™ Discrimination
Target Identification2 Dimensional Smartfind™ Size / Conductivity and Ferrous characteristics Conductivity 1-50, Ferrous 1-35
Sensitivity AdjustmentFully Automatic; adjustable to be more aggressive or conservative, Manual Setting 1-30
Sensitivity GaugeAuto Level, Manual Level, Suggested Level
ThresholdFine adjustment level from 1-50
Recovery SpeedSelectable Fast & Deep
Trash DensityLow for areas with isolated targets or High, for areas with more trash
Noise CancelAutomatic & Manual selection of 11 channels
Audio Response4 Settings: Normal, Long, Smooth, Pitch Hold
Tone ID Number of Tones1, 2, 4 and Multi-tone; customizable for Conductivity or Ferrous response
Tone ID Variability30 adjustable steps for better Target Identification
HeadphoneInput ¼” 100Ω Stereo Jack
Ground Balance ModesAuto Ground Compensation - Advanced Digital Filtering
Ground SettingsNeutral for most ground conditions, Difficult for more mineralized soils
Batteries1600 mAh NiMH or Alkaline batteries
Low Battery Audio AlarmAudio and visual indication
Visual DisplayLarge 3.4” (8.65cm) greyscale LCD panel with Contrast adjustment and Backlight
PatentsUS 4890064; US 5537041; US 5506506