Cooling power consumption
Heating power consumption
Cooling running current
Heating running current
Inrush current (L.R.A) <Max. running current>
2.02/2.02
2.16/2.16
10.4/10.4
11.1/11.1
5 <17>
(220-240V 50Hz/220V 60Hz)
Item
Model
FDC71VN FDC100VN FDC125VN FDC140VN
kW
A
A
5 <24>
2.62/2.62
2.60/2.60
11.7/12.3
11.6/12.2
3.91/3.91
3.63/3.63
17.3/18.2
16.2/16.9
4.51/4.51
4.40/4.40
20.4/21.4
19.5/20.4
Cooling power consumption
Heating power consumption
Cooling running current
Heating running current
Inrush current (L.R.A) <Max. running current>
(380-415V 50Hz/380V 60Hz)
Item
Model
FDC100VS FDC125VS FDC140VS
kW
A
A
2.62/2.62
2.60/2.60
3.8/4.0
3.8/4.0
3.91/3.91
3.63/3.63
5.5/5.9
5.1/5.5
5 <15>
4.51/4.51
4.40/4.40
6.5/6.9
6.3/7.0
(3) Operation chart
The V Multi is a system that allows for different models and capacities of indoor units to be connected so the individual operating
characteristics of the indoor and outdoor are provided. Use the procedure shown in Item (c) to calculate the combined operating
characteristics.
(a) Operating characteristic of outdoor unit
Cooling power consumption
Heating power consumption
Cooling running current
Heating running current
Inrush current (L.R.A) <Max. running current>
(380-415V 50Hz/380V 60Hz)
Item
Model
FDC200VS
6.34/6.34
6.20/6.20
9.1/9.1
9.0/9.0
5 <19>
8.71/8.71
7.75/7.75
12.7/12.7
11.4/11.4
5 <22>
FDC250VS
kW
A
A
Note(1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
ISO-T1 “UNITARY AIR-CONDITIONERS”
(b) Operating characteristic of indoor unit
Notes(1) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
ISO-T1 “UNITARY AIR-CONDITIONERS”
Notes(2) The values shown in the above table are common to both cooling and heating operations.
Model
Item
FDT40VD FDT50VD FDT60VD FDT71VD FDT100VD FDT125VD
Cooling power consumption
kW
0.03-0.03/0.03 0.04-0.04/0.04 0.10-0.10/0.10 0.14-0.14/0.14
Heating power consumption 0.03-0.03/0.03 0.04-0.04/0.04 0.10-0.10/0.10 0.14-0.14/0.14
Cooling running current
A
0.20-0.18/0.20 0.20-0.18/0.20 0.30-0.28/0.30 0.45-0.40/0.45
Heating running current 0.20-0.18/0.20 0.20-0.18/0.20 0.30-0.28/0.30 0.45-0.40/0.45
FDT Series (220-240V 50Hz/220V 60Hz)
Model
Item
FDEN40VD FDEN50VD FDEN60VD FDEN71VD FDEN100VD FDEN125VD
Cooling power consumption
kW
0.05-0.06/0.06 0.10-0.11/0.11 0.14-0.16/0.16 0.16-0.18/0.20
Heating power consumption 0.05-0.06/0.06 0.09-0.10/0.10 0.13-0.15/0.15 0.15-0.17/0.18
Cooling running current
A
0.25-0.26/0.29 0.46-0.48/0.50 0.65-0.67/0.77 0.77-0.78/0.91
Heating running current 0.23-0.25/0.28 0.42-0.44/0.46
0.10-0.12/0.14
0.10-0.11/0.13
0.50-0.53/0.67
0.46-0.48/0.63 0.59-0.63/0.70 0.70-0.72/0.83
FDEN Series (220-240V 50Hz/220V 60Hz)