(3)
Ceiling concealed type (SRR)
Model
Item
SRR25ZS-W
Indoor unit SRR25ZS-W Outdoor unit SRC25ZS-WA2
Power source 1 Phase, 220 - 240V, 50Hz
Operation
data
Nominal cooling capacity (range) kW 2.5 ( 0.9 (Min.) - 3.2 (Max.))
Nominal heating capacity (range) kW 2.9 ( 0.9 (Min.) - 4.4 (Max.))
Heating capacity (H2) kW —
Power consumption
Cooling
kW
0.62 ( 0.19 - 0.99 )
Heating 0.65 ( 0.19 - 1.32 )
Heating (H2) —
Max power consumption 1.65
Running current
Cooling
A
3.2 / 3.1 / 3.0 (220/ 230/ 240V)
Heating 3.4 / 3.2 / 3.1 (220/ 230/ 240V)
Inrush current, max current 3.4 / 3.2 / 3.1 (220/ 230/ 240V)
Max.
9
Power factor
Cooling
%
87
Heating 88
EER Cooling 4.03
COP
Heating 4.46
Heating (H2) —
Sound power level
Cooling
dB(A)
56 58
Heating 59 58
Sound pressure level
①
Cooling Hi: 37 Me: 33 Lo: 30 ULo: 24 47
Heating Hi: 40 Me: 37 Lo: 34 ULo: 28 47
Sound pressure level
②
Cooling Hi: 31 Me: 28 Lo: 26 ULo: 21 47
Heating Hi: 33 Me: 30 Lo: 28 ULo: 23 47
Sound pressure level
③
Cooling Hi: 39 Me: 35 Lo: 32 ULo: 25 47
Heating Hi: 44 Me: 41 Lo: 38 ULo: 31 47
Silent mode sound pressure level — Cooling:41 / Heating:42
Exterior dimensions (Height x Width x Depth) mm 200 x 750 x 500 540 x 780(+62) x 290
Exterior appearance
(Equivalent color : Munsell, RAL)
—
Stucco white
( 4.2Y 7.5/1.1 ) , ( 7044 )
Net weight kg 20.5 31.0
Compressor type & Quantity — RM-C5077SBE71( Rotary type ) x 1
Compressor motor (Starting method) kW — 0.75 ( Inverter driven )
Refrigerant oil (Amount, type) L — 0.30 ( DIAMOND FREEZE MB75 )
Refrigerant (Type, amount, pre-charge length) kg R32 0.62 in outdoor unit (Incl. the amount for the piping of 15m )
Heat exchanger Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Fan type & Quantity Centrifugal fan x 2 Propeller fan x 1
Fan motor (Starting method) W 51 x1 (Direct drive) 24 x1 (Direct drive)
Air flow
Cooling
m
3
/min
Hi: 9.5 Me: 8.0 Lo: 6.5 ULo: 4.5 27.4
Heating Hi: 10.0 Me: 9.0 Lo: 8.0 ULo: 6.0 23.6
Available external static pressure Pa 35 (Initial static pressure with air filter:5Pa) 0
Outside air intake Not possible —
Air filter, Quality / Quantity Polypropylene net x 1 —
Shock & vibration absorber Cushion rubber ( for fan motor )
Rubber sleeve ( for fan motor & compressor )
Electric heater — Defrost heater 230V 110W
Operation
control
Remote control Wireless remote control
Room temperature control Microcomputer thermostat
Operation display RUN: Green, TIMER: Yellow, HI POWER: Green, ECONO: Green
Safety equipments
Compressor overheat protection, Overcurrent protection, Drain error protection
Frost protection, Serial signal error protection, Indoor fan motor error protection
Heating overload protection( High pressure control ), Cooling overload protection
Installation
data
Refrigerant piping size (O.D.) mm Liquid line:
φ
6.35 (1/4") Gas line:
φ
9.52 (3/8")
Connecting method Flare connection Flare connection
Attached length of piping m — —
Insulation for piping Necessary ( Both sides ), independent
Refrigerant line (one way) length m Max.20
Vertical height diff. between O/U and I/U m Max.10 ( Outdoor unit is higher ) / Max.10 ( Outdoor unit is lower )
Drain hose Hose connectable ( VP25 )
Hole size
φ
20 x 2 pcs., Hole size
φ
16 x 9 pcs.
Drain pump, max lift height mm Built-in, MAX600 —
Recommended breaker size A 16
L.R.A. (Locked rotor ampere) A 3.7 / 3.6 / 3.4 (220/ 230/ 240V)
Interconnecting wires Size x Core number 1.5mm
2
x 4 cores (Including earth cable) / Terminal block (Screw fixing type)
IP number IPX0 IPX4
Standard accessories
Mounting kit, Joint for drain piping
Option parts Wired remote control, Interface kit ( SC-BIKN2-E ), Bottom air inlet kit
(5) Mike positions of measureing sound pressure level
of indoor unit is shown below.
Notes (1) The data are measured at the following conditions.
The pipe length is 5m.
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) Sound level indicates the value in an anechoic chamber. During operation these values
are somewhat higher due to ambient conditions.
(4) Select the breaker size according to the own national standard.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1
Heating 20˚C — 7˚C 6˚C ISO5151-H1
Heating (H2) 20˚C — 2˚C 1˚C ISO5151-H2
External static
pressure
for
②
,
③
: 10Pa
①
③
②
B
RWA000Z282
-
15
-
'21 • SRK-T-299