18
-
'21 • KX-T-380
3.
RANGE OF USAGE & LIMITATIONS
• Single use (also for combined use)
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
First branch
50m
MAX.
90m
MAX. 90m
MAX. 90m
MAX. 18m
(Outdoor unit is lower : 40m)
MAX.
130m
50m
MAX.
130m
MAX. 18m
MAX. 18m MAX. 18m
MAX. 18m
MAX. 18m
(Outdoor unit is lower : 40m)
(Lowest indoor unit)
(Highest indoor unit)
(Highest indoor unit)
(Lowest indoor unit)
First branch
(Header)
denotes
System
FDC(S)335(C)KXZA2 FDC(S)400(C)KXZA2
Refer to page 23.
1 to 29 units 1 to 34 units
1 to 24 units
Item
Indoor air temperature
(Upper, lower limits)
Outdoor air temperature
(Upper, lower limits)
Single direction piping length Actual length : 160m or less, Equivalent length : 185m or less
Total piping length
(2)
Main pipe length
1000m or less
130m or less
90m or less (However, difference between the longest and shortest piping : 40m or less
(6)
)
5 min or more (from stop to stop or from start to start)
3 min or more
Within 10% of rated voltage
50m or less (Max. 90m or less)
(5), (7)
40m or less
(3)
18m or less (Max. 30m or less)
(8)
Allowable pipe length from the first branching
18m or less
Elevation difference between the first branching point and the indoor unit
Number of connected units
Connectable capacity
(1)
FDC(S)280(C)KXZA2
140
-
364 168
-
435 200
-
520
Outdoor unit is higher
Outdoor unit is lower
Indoor units
that can be
used in
combination
Difference in
height between
indoor and outdoor
units
Difference in the elevation of indoor units in a system
Indoor unit atmosphere (behind ceiling)
temperature and humidity
Only models FDT, FDTC, FDTW, FDTS, FDTQ,
FDU, FDUM, FDUT, FDUH, FDU-F
1 cycle time
Stop time
Voltage fluctuation
Phase unbalance
Compressor
stop/start
frequency
Power source
voltage
Voltage drop during start
Dew point temperature 28 or less, relative humidity 80% or less
(FDE, FDK, FDFL, FDFU, FDFW : Dew point temperature 23 or less, relative humidity 80% or less)
Within 3%
Within 15% of rated voltage
Notes (1) When connecting the indoor unit type FDK, FDFL, FDFU or FDFW Series, limit the connectable capacity not higher than 130%.
(2) When the pipe extension length exceeds 510m, additional refrigerant oil must be charged (1,000 cc).
(3) It must be less than 30m when conducting the cooling operation with the outdoor air temperature lower than 10
C.
(4) If Superlink I (previous Superlink) is selected, all the range of usage and limitations, not only the limitations of connectable indoor capacity
and connectable number of indoor unit but also of the piping length, operating temperature range and etc., become same as those of KX4 (See
technical manual ’07·KX·KXR-T-114.). In addition to above limitations, all of new functions for KX6 and KXZ such as automatic address
setting function for multiple refrigerant systems and etc. will be cancelled.
(5) When it is required to install in a range of 50 to 90m, the limitation of use, etc. are different from those described here. For details, refer to
page 24.
(6) When it is required to install in the difference between the longest and shortest piping more than 40m, refer to page 23.
(7) It must be 40m or less, when it is required to use at the outdoor air temperature higher than 43°C.
(8) If the difference in the elevation is 18 to 30m, the limitation of use, etc are different from those described here. For details, refer to page 26.
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
First branch
50m
MAX.
90m
(2)
MAX.
40m
(2)
MAX. 90m
MAX. 90m
(2)
MAX. 18m
(Outdoor unit is lower : 40m)
MAX.
130m
50m
MAX.
130m
MAX. 18m
MAX. 18m
MAX.
40m
(2)
MAX. 18m
MAX. 18m
MAX. 18m
(Outdoor unit is lower : 40m)
(Lowest indoor unit)
(Highest indoor unit)
(Highest indoor unit)
(Lowest indoor unit)
First branch
(Header)
denotes
System
FDC(S)500(C)KXZA2 FDC(S)560(C)KXZA2
Refer to page 23.
1 to 43 units 1 to 48 units
1 to 39 units
Item
Indoor air temperature
(Upper, lower limits)
Outdoor air temperature
(Upper, lower limits)
Single direction piping length
Actual length : 160m or less, Equivalent length : 185m or less
Total piping length
(2)
Main pipe length
1000m or less
130m or less
90m or less (However, difference between the longest and shortest piping : 40m or less
(6)
)
5 min or more (from stop to stop or from start to start)
3 min or more
Within 10% of rated voltage
50m or less (Max. 90m or less)
(5), (7)
40m or less
(3)
18m or less (Max. 30m or less)
(8)
Allowable pipe length from the first branching
18m or less
Elevation difference between the first branching point and the indoor unit
Number of connected units
Connectable capacity
(1)
FDC(S)450(C)KXZA2
225
-
585
250
-
650
FDC(S)475(C)KXZA2
1 to 41 units
238
-
617 280
-
728
Outdoor unit is higher
Outdoor unit is lower
Indoor units
that can be
used in
combination
Difference in
height between
indoor and outdoor
units
Difference in the elevation of indoor units in a system
Indoor unit atmosphere (behind ceiling)
temperature and humidity
Only models FDT, FDTC, FDTW, FDTS, FDTQ,
FDU, FDUM, FDUT, FDUH, FDU-F
1 cycle time
Stop time
Voltage fluctuation
Phase unbalance
Compressor
stop/start
frequency
Power source
voltage
Voltage drop during start
Dew point temperature 28 or less, relative humidity 80% or less
(FDE, FDK, FDFL, FDFU, FDFW : Dew point temperature 23 or less, relative humidity 80% or less)
Within 3%
Within 15% of rated voltage

Other manuals for Mitsubishi Heavy Industries KXZ Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries KXZ Series and is the answer not in the manual?

Mitsubishi Heavy Industries KXZ Series Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelKXZ Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals