Page #119 background image
-
117
-
'18 • SCM-T-251
Models SCM50ZS-S1, 60ZM-S1
Gas line
Liquid lin
e
(
ȭ6.35)
(
ȭ6.35)
(
ȭ6.35)
EEVA
Strainer
EEVB
EEVC
Service valve (Gas)
Outdoor Unit
Indoor Unit
Sensor
(Th2
2) (Thi-R)
Heat exchanger
Sensor
(Th1) (Thi-A)
Sensor
(Th2
1) (Thi-R)
Sensor
(Tho-D)
Sensor
(Tho-A)
Accumulator
Sensor
(Tho-S)
Service valve
(Liquid)
Electronic
expansion valve
Compressor
4-way valve
Discharge
Suction
Sensor
(Tho-R)
Heat exchanger
Cooling cycle
Heating cycle
ȭ9.52 or ȭ12.7)
1
ȭ9.52 or ȭ12.7)
1
ȭ9.52 or ȭ12.7)
1
Muffler
Accumulator
Receiver
Capillary
tube
Capillary
tube
1 Gas line
Model 20,25,35 :
ȭ9.52
Model 50,60 :
ȭ
12.7
2 Humidity sensor
SRK

ZSX, SRK35, 50ZS and SRF series only.
Humidity
sensor
2
(Th3)
Capillary
tube
3. PIPING SYSTEM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SCM50ZS-S1 and is the answer not in the manual?

Mitsubishi Heavy Industries SCM50ZS-S1 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSCM50ZS-S1
CategoryAir Conditioner
LanguageEnglish

Related product manuals