182
-
'18 • SCM-T-251
(25) Fan control at heating startup
(a) Starting conditions
At the start of heating operation, if the difference of setting temperature and return air temperature is 5°C or higher
after the end of hot start control, this control is performed.
(b) Contents of control
(i) Sampling is made at each minute and, when the indoor unit heat exchanger temperature (detected with Thi-R) is 37°C
or higher, present number of revolutions of indoor unit fan speed is increased by 10 min
-1
.
(ii) If the indoor unit heat exchanger temperature drops below 37°C at next sampling, present number of revolutions of
indoor unit fan speed is reduced by 10 min
-1
.
(c) Ending conditions
IndoorfanspeedisreducedtothesettingairowvolumewhenthecompressorOFFisestablishedandat30minutes
after the start of heating operation.
(26) Room temperature detection temperature compensation during heating
With the standardspecication, thecompressor isturned ON/OFF with the thermostat setting temperature.When the
thermostat is likely to turn OFF earlier because the unit is installed at the ceiling where warm air tends to accumulate, the
setting can be changed with the wired remote control indoor unit function “
”. The compressor and the heater are
turned ON/OFF at one of the setting temperature +3, +2 or +1°C in order to improve the feeling of heating. The setting
temperature, however, has the upper limit of 30°C.
Compressor Compressor
Standard
Operation
Stop
Setting temperature
-1 +1
Room temperature (deg)
Operation
Stop
Setting temperature
+2 +4
Room temperature (deg)
When it is set at +3°C
(27) Return air temperature compensation
This is the function to compensate the deviation between the detection temperature by the return air temperature sensor
and the measured temperature after installing the unit.
(a) It is adjustable in the unit of 0.5°C with the wired remote control indoor unit function “RETURN AIR TEMP”.
• +1.0°C, +1.5°C, +2.0°C • -1.0°C, -1.5°C, -2.0°C
(b) Compensated temperature is transmitted to the remote control and the compressor to control them.
Note (1) The detection temperature compensation is effective on the indoor unit sensor only.
(28) High power operation (RC-EX3 only)
Itoperatesatwiththesettemperature.xedat16°C for cooling, 30°C for heating and maximum indoor fan speed for 15
minutes maximum.
(29) Energy-saving operation (RC-EX3 only)
It operates with the setting temperature fixed at 28°C for cooling, 22°C for heating or 25°C for auto. When fan control
in cooling/heating thermo-OFF setting is "Set fan speed", fan speed during thermo-OFF is changed to "Low"(Maximum
capacity is restricted at 80%.)
(30) Warm-up control (RC-EX3 only)
Operation will be started 5 to 60 minutes before use according to the forecast made by the microcomputer which
calculates when the operation should be started in order to warm up the indoor temperature near the setting temperature at
the setting time of operation start.
(31) Home leave mode (RC-EX3 only)
When the unit is not used for a long period of time, the room temperature is maintained at a moderate leval, avoiding
extremely hot or cool temperature.
(a) Cooling or heating is operated according to the outdoor temperature (factory setting 35°C for cooling, 0°C for heating)
and the setting temperature. (factory setting 33°C for cooling, 10°C for heating)
(b) Setting temperature and indoor fan speed can be set by RC-EX3.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SCM50ZS-S1 and is the answer not in the manual?

Mitsubishi Heavy Industries SCM50ZS-S1 Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSCM50ZS-S1
CategoryAir Conditioner
LanguageEnglish

Related product manuals