29
-
'19 • SCM-SM-281
(b) Swing
Flap moves in upward and downward directions continuously.
In HEAT operation In COOL, DRY, FAN operation
Approx. 35°
Approx. 65°
Approx.
20°
Approx. 59°
(c) Memory flap
When you press the AIR FLOW (UP/DOWN) button once while the ap is operating, it stops swinging at the position.
Since this angle is memorized in the microcomputer, the ap will automatically be set at this angle when the next opera-
tion is started.
(d) When not operating
The ap returns to the position of air ow directly below, when operation has stopped.
(8) Timer operation
(a) Comfortable timer setting (ON timer)
If the timer is set at ON when the operation select switch is set at the cooling or heating, or the cooling or heating in
auto mode operation is selected, the comfortable timer starts and determines the starting time of next operation based
on the initial value of 15 minutes and the relationship between the room temperature at the setting time (temperature of
room temperature sensor) and the setting temperature.
(b) Sleep timer operation
Pressing the SLEEP button causes the temperature to be controlled with respect to the set temperature.
(c) OFF timer operation
The Off timer can be set at a specic time (in 10-minute units) within a 24-hour period.
(9) Outline of heating operation
(a) Operation of major functional components in heating mode
(b) Details of control at each operation mode (pattern)
(i) Fuzzy operation
Deviation between the room temperature setting correction temperature and the suction air temperature is calculated in
accordance with the fuzzy rule, and used for control of the air capacity and the compressor speed.
When the defrost operation, protection device, etc. is actuated, operation is performed in the corresponding mode.
ON OFF OFF
ON ON OFF
ON
OFF
(few minutes ON)
OFF
ON ON(HOT KEEP) OFF
OFF
OFF
(3 minutes ON)
OFF
OFF
Thermostat ON Thermostat OFF Defrost Failure
Heating
Compressor
Indoor fan motor
Outdoor fan motor
4-way valve
20
-
115rps
20
-
115rps
20
-
66rps 20
-
72rps 20
-
84rps
20
-
48rps 20
-
54rps 20
-
62rps
Model
Fan speed
SKM20ZSP-W SKM25ZSP-W SKM35ZSP-W
AUTO
MED
HI
LO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SCM50ZS-W and is the answer not in the manual?

Mitsubishi Heavy Industries SCM50ZS-W Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSCM50ZS-W
CategoryAir Conditioner
LanguageEnglish

Related product manuals