- 32 -
Selection of installation location
○ The appliance must be installed at a location with the vents and air intake being 10cm away from
walls.
(In case the fence is 1.2m or above in height, or is overhead, the sufficient space between the
unit and wall shall be secured.)
○ When the unit is installed, the space of the following dimension shall be secured.
○ Removal
① Remove the air inlet grille.
② Remove the 2 screws
securing the front panel.
③ Remove the 3 latches on
the upper part of the front
panel and remove the front
panel from the unit.
○ Installation
① Remove the air filter.
② Cover the unit with the
front panel.
③ Tighten the 2 screws to
secure the front panel.
④ Mount the air filter.
⑤ Mount the air inlet grille.
5.2 Installation of indoor unit
How to remove and install the front panel
Mountng of mounting plate
No obstacles (Service
space for electrical
parts)
Caution
If the wall is 1.2m or above in
height or there is a ceiling, the
sizes should be greater than
those indicated above.
Fixing the mounting plate
Firstly find the position of
support or columella in the wall.
Check that the mounting
location is level and then fix the
unit more securely.
○ In the loose state, use
four screws to adjust the
mounting plate
horizontally.
○ Turn the mounting
plate with the standard
hole as the center to
make it level.
Setting the relationship between
plate and indoor unit
(Indoor unit) (Front view)
Fixing on the concrete wall