A - 7 A - 7
3.2.10 Alert function.................................................................................................................................... 3-18
3.2.11 Control output setting at CPU stop error occurrence function....................................................... 3-23
3.2.12 Program control function................................................................................................................. 3-24
3.2.13 Cascade control function ................................................................................................................ 3-32
3.2.14 Scaling function ............................................................................................................................... 3-34
3.2.15 Simplified analog I/O function ......................................................................................................... 3-35
3.2.16 Q62HLC control status controlling output signal and buffer memory settings and control status
......................................................................................................................................................... 3-36
3.3 Sampling Period and Control Output Period........................................................................................... 3-40
3.4 I/O Signals Transferred to/from the Programmable Controller CPU...................................................... 3-41
3.4.1 I/O signal list ...................................................................................................................................... 3-41
3.4.2 Input signal functions ........................................................................................................................ 3-42
3.4.3 Output signal functions...................................................................................................................... 3-46
3.5 Buffer Memory.......................................................................................................................................... 3-49
3.5.1 Buffer memory list ............................................................................................................................. 3-49
3.5.2 Error code (buffer memory address 0: Un\G0) ................................................................................ 3-60
3.5.3 Alert definition (buffer memory address 5,6: Un\G5, Un\G6) .......................................................... 3-61
3.5.4 Measured value (PV value) (buffer memory address 9,10: Un\G9, Un\G10) ................................. 3-61
3.5.5 Manipulated value (MV value) (buffer memory address 13, 14: Un\G13, Un\G14)........................ 3-61
3.5.6 Approach flag (buffer memory address 17, 18: Un\G17, Un\G18).................................................. 3-62
3.5.7 Set value monitor (buffer memory address 25, 26: Un\G25, Un\G26)............................................ 3-62
3.5.8 Cold junction temperature measured value (buffer memory address 29: Un\G29)........................ 3-62
3.5.9 Control mode monitor (buffer memory address 30: Un\G30) .......................................................... 3-62
3.5.10 FeRAMs PID constant read/write flag (buffer memory address 31: Un\G31)............................... 3-63
3.5.11 Input range (buffer memory address 32, 64: Un\G32, Un\G64).................................................... 3-65
3.5.12 Stop mode setting (buffer memory address 33, 65: Un\G33, Un\G65)......................................... 3-67
3.5.13 Set value (SV) setting (buffer memory address 34, 66: Un\G34, Un\G66)................................... 3-67
3.5.14 PID constant setting (buffer memory address 35 to 37, 67 to 69:
Un\G35 to Un\G37, Un\G67 to Un\G69) ........................................................................................ 3-68
3.5.15 Alert setting value 1 to 4 (buffer memory address 38 to 41, 70 to 73:
Un\G38 to Un\G41, Un\G70 to Un\G73) ........................................................................................ 3-68
3.5.16 Upper/lower output limiter (buffer memory address 42, 43, 74, 75:
Un\G42, Un\G43, Un\G74, Un\G75)............................................................................................... 3-69
3.5.17 Output variation limiter (buffer memory address 44, 76: Un\G44, Un\G76).................................. 3-69
3.5.18 Sensor compensation value setting (buffer memory address 45, 77: Un\G45, Un\G77)............. 3-69
3.5.19 AT differential gap (buffer memory address 46, 78: Un\G46, Un\G78)......................................... 3-70
3.5.20 AT additional lag (buffer memory address 47, 79: Un\G47, Un\G79)........................................... 3-70
3.5.21 Primary delay digital filter setting (buffer memory address 48, 80: Un\G48, Un\G80) ................. 3-71
3.5.22 Control response parameter (buffer memory address 49, 81: Un\G49, Un\G81) ........................ 3-72
3.5.23 Control mode (buffer memory address 50, 82: Un\G50, Un\G82) ................................................ 3-73
3.5.24 MAN output setting (buffer memory address 51, 83: Un\G51, Un\G83) ....................................... 3-74
3.5.25 Setting change rate limiter (buffer memory address 52, 84: Un\G52, Un\G84)............................ 3-74
3.5.26 AT bias (buffer memory address 53, 85: Un\G53, Un\G85) .......................................................... 3-75
3.5.27 Forward/reverse action setting (buffer memory address 54, 86: Un\G54, Un\G86)..................... 3-75
3.5.28 Upper/lower setting limiter (buffer memory address 55, 56, 87, 88:
Un\G55, Un\G56, Un\G87, Un\G88)............................................................................................... 3-76
3.5.29 Program control RUN/RESET (buffer memory address 57, 89: Un\G57, Un\G89)...................... 3-76
3.5.30 Loop disconnection detection judgment time
(buffer memory address 59, 91: Un\G59, Un\G91)........................................................................ 3-77

Table of Contents

Other manuals for Mitsubishi Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Q Series and is the answer not in the manual?

Mitsubishi Q Series Specifications

General IconGeneral
BrandMitsubishi
ModelQ Series
CategoryControl Unit
LanguageEnglish

Related product manuals